St Edward's School | Fire Alarm Panel and Detector Replacement

New fire alarm panels and detectors delivered across an entire school site during the summer holidays.

The summer holidays were a busy time for our fire and security team, who worked across St Edward’s School in Poole, Dorset, replacing fire alarm panels and detectors throughout every building on site. With much of the equipment reaching around ten years in service, the work was timed to finish before pupils and staff returned for the new term in September.

Client Request and Scope of Work

St Edward’s School asked Unique Fire and Security to replace every detector on site that had passed its manufacturer recommended lifespan, along with simplifying and modernising the fire panel network across the main building. The scope covered three hundred and twenty eight smoke detectors, twenty eight heat detectors and eleven multi sensor detectors, replaced throughout every classroom, corridor and communal space on site. Two of the existing fire panels were removed altogether, with their loop cables extended and rejoined into the main panel to reduce the number of panels the school needed to manage day to day. The remaining five panels were replaced entirely.

Products and Timeline

All detectors were replaced with new Apollo Discovery smoke, heat and multi sensor devices, giving a consistent, modern standard across every building. The five remaining fire panels were replaced with new Advanced MxPro5 panels, each fitted with a fifty zone LED attachment, a key enable switch and a new network card, with the two removed panels’ loop cables rerouted through additional loop cards on the retained panels. Around four hundred metres of new fire panel cable, along with all fixings and trunking, was installed to support the works. High level access equipment was brought in to reach detectors fitted at height, including in the school’s sports hall. The whole project was completed within the summer holiday period so pupils and staff returned to a fully working system without any disruption to term time. Once every detector and panel was in place, the entire system was tested and commissioned zone by zone, with a certificate issued to confirm the completed works.

Challenges

Replacing detection equipment across an entire school site within a single summer holiday period meant careful planning of work across multiple buildings and rooms at once, so the whole job could be finished before term restarted. Reaching detectors fitted at height, including in the sports hall roof, needed high level access equipment brought onto site and coordinated safely alongside the rest of the works. Simplifying the panel network, removing two panels and rerouting their loop cables into the main panel, also needed careful sequencing so every zone continued reporting correctly once the works were finished.

Results

St Edward’s School now has newly replaced fire alarm detectors and panels across the whole site, three hundred and sixty seven new detectors and five new Advanced MxPro5 panels, all tested, commissioned and certified before the start of the new term. The simplified panel network gives the school fewer panels to manage day to day, while the new detectors and panels bring the whole site up to a consistent, modern standard. The work was completed entirely within the summer holidays, so pupils and staff returned to a fully compliant, fully tested system with no disruption to the school day.

Why Unique

Unique Fire and Security works with schools and colleges across Dorset, Hampshire, Devon and Cornwall, renewing fire alarm equipment on a timescale planned around term dates so term time is never disrupted. St Edward’s School chose Unique to manage a project of this scale, hundreds of detectors and every fire panel on site, from a single team, start to finish. It is this ability to plan and deliver large scale works within a tight holiday window that keeps schools returning to Unique as a trusted long term safety partner.